精品欧美-日韩毛片在线-免费成人小视频-韩国av一区-欧美色拍-91在线精品播放-欧美性大战久久久-亚洲最大成人网色-日韩一卡二卡三卡四卡-黄色片网站在线-啊啊啊快点视频

GST-Sepharose FF Gravity Prepacked Column

GST-Sepharose FF Gravity Prepacked Column

【Numbering】BK-NRPB08S 【CAS】CAS
【Item No.】BK-NRPB08S-Z25 【specification】
5 minutes to choose the product plan

E-mail:cro@szbknm.com




Product name: GST-Sepharose FF


English name: Glutathione NUPharose Fast Flow, GST NUPharose FF


Specifications: 20 ml, 100 ml, 1 L, 1 ml pre-packed column, 5 ml pre-packed column, special specifications customized


Transportation: 2 ~ 30℃, normal pressure, avoid light


Storage: 20% ethanol, 2 ~ 8℃


Shelf life: 3 years






Related introduction:


GST-Sepharose FF is a bio-affinity chromatography separation medium formed by bonding glutathione to agarose gel microspheres. The product retains the excellent hydrophilicity of agarose and the large grid structure, and has good compatibility with biologically active macromolecules. It has the characteristics of high capacity, low non-specific adsorption, and fast flow rate. It is mainly used for grain Separation and purification of glutathione transferase labeled protein (GST fusion protein), glutathione transferase and glutathione-dependent proteins.






Technical index:


Matrix


4% highly cross-linked agarose gel


Ligand


Glutathione


Ligand Density


≥10 μmol/ml


Filler particle size


60 ~ 180 μm


Protein load


About 10mg glutathione-S-transferase/mL


Maximum flow rate


300 cm/h


Recommended flow rate


20 ~ 100 cm/h


Back pressure resistant


0.3 MPa


pH stability


3 ~ 12 (long time); 3 ~ 13 (short time)


Chemical stability


Stable in the following solutions: commonly used aqueous buffers; 1 M acetic acid (pH 4.0); 6 M guanidine hydrochloride; 70% ethanol.






Instructions:


  1. Column loading


  1.1 Prepare initial buffer (equilibrium solution) and elution buffer according to the nature of the separation target.


  1.2 Drain the gel and wash it twice with distilled water to remove the stored ethanol, mix it with distilled water and degas it.


  1.3 Fix the column vertically, moisten the bottom end with water or buffer and keep the liquid level for a period of time.


  1.4 Use a glass rod to guide the homogenate and pour it into the column along the inner wall of the column at one time to allow the gel to settle freely in the column.


1.5 Connect the movable column head at the top of the column, turn on the peristaltic pump, let the buffer flow through 5 column volumes at the operating flow rate during use, and then use 1.5 times the operating flow rate to flow through 5 column volumes, adjust the adapter column head to make it as close as possible to the glue surface , And finally equilibrate the column with 2 to 3 column volumes of buffer.






Notice:


1) No air bubbles can be introduced during all operations to ensure the uniformity of the glue filling.


2) If 1.2 is done unconditionally, there are bubbles in the packing layer, and the column can be loaded twice to remove the stored ethanol and bubbles.


3) The solution prepared by reagents such as ethanol needs to be degassed.


  2. Balance


   Equilibrate the column with the equilibration buffer at the operating flow rate, and observe the changes in the detector until the conductivity, pH and other parameters remain unchanged. The recommended binding equilibration buffer is: 10 mM PBS (140 mM NaCl, 2.7 mM KCl, 10 mM Na2HPO4, 1.8 mM KH2PO4, pH 7.4).


  3. Sample loading


Switch the switching valve to load the sample. The sample amount is selected according to the nature of the sample and the amount of the chromatography medium. The linear experiment can also be performed to find the best sample amount; sample pretreatment: replacement of buffer, clarification and filtration (0.45, 0.22) μm) and so on.


  4. Rinse


   Wash the loaded chromatography column with 2 to 3 column volumes of equilibration buffer and observe the changes of the detector until the conductivity, pH and other parameters remain unchanged, at which time the unexchanged components are washed out.


   5. Elution


   It is generally recommended to use 10 mM reduced glutathione solution (may contain buffer components) for elution. The recommended elution buffer is: 50 mM Tris-HCl, 10 mM reduced glutathione (GSH), pH 8.0.


   6. Regeneration


   Wash 3 to 5 column volumes with distilled water at the operating flow rate, and then wash with a balance solution to balance 3 to 5 column volumes.


   If there are inactivated proteins or lipids that cannot be washed off during regeneration, they can be removed by cleaning-in-place (CIP).


  7. Cleaning-in-place (CIP)


To remove precipitates and denatured proteins: wash with 2 CV 6 M guanidine hydrochloride, and immediately wash with 10 mM PBS (pH 7.4) for 5 CV.


Removal of strong hydrophobin: Wash with 3 ~ 4 CV 70% ethanol, and immediately wash with 10 mM PBS (pH 7.4) for 5 CV.






Precautions:


Recommended flow rate


Pre-packed column volume (ml)


1 ml


5 ml


10 ml


Flow rate (ml /min)


0.2


1





Warm tips: Suzhou Beike nano products are only used for scientific research, not for human body,different batches of products have different specifications and performance

Message

Name: *
Mobile: *
E-mail: *
Content:
 
Scan code concerns WeChat official account
QQCommunication group:1092348845
Warm tips: Suzhou Beike nano products are only used for scientific research, not for human body,different batches of products have different specifications and performance.The website pictures are from the Internet. The pictures are for reference only. Please take the real object as the standard. In case of infringement, please contact us to delete them immediately.
    GST-瓊脂糖凝膠FF重力預裝柱

Previous: the end...

Next: Dextrin Sepharose FF

advisory
phone
cro@szbknm.com
Tel:+8618915694570
scan

scan
WeChat

主站蜘蛛池模板: 万安县| 屯门区| 白山市| 西峡县| 铁力市| 乌苏市| 青铜峡市| 连城县| 襄城县| 额尔古纳市| 湟中县| 栾城县| 西青区| 洛隆县| 北京市| 姚安县| 白水县| 信宜市| 北流市| 慈利县| 上虞市| 阿合奇县| 海晏县| 新余市| 临沧市| 榆林市| 武川县| 金门县| 长兴县| 鸡泽县| 吴桥县| 绥江县| 清苑县| 望都县| 方山县| 绵阳市| 延长县| 英德市| 凤山市| 通化市| 清河县|